65mm Kingspan Kooltherm K110 Soffit Insulation Board (pack of 4)
Guide Price
65mm Kingspan Kooltherm K110 Soffit Insulation Board (pack of 4)
Guide Price: £373.33 (£448.00 inc VAT)
Price per m2: £32.41/m2 (£38.89 inc VAT)
- Product Code: A1-2086
- Delivery Time: 7 - 10 days
- Brand: Kingspan (Tech. support: 01544388601)
- Model and Size: 2400x1200mm - 11.52m2
- Weight: 29.95kg
Our ratings on 29-03-2024:
4.6 out of 5 - Excellent
4.8 out of 5
65mm Kingspan Kooltherm K110 Soffit Insulation Board (pack of 4)
Width: 1200mm
Length: 2400mm
Pack Quantity: 4
Pack Coverage: 11.52m2
Density: 40kg/m3
Weight/m2: 2.6kg
Weight: 29.95kg
Thermal Conductivity: 0.019W/mK
R-Value: 3.42m2K/W
Compressive Strength: 100kPa
65mm Kingspan Kooltherm K110 Soffit Board is a premium performance lower lambda insulation with a fibre-free rigid thermoset phenolic core, a 6mm glass tissue based facing on its front surface and low emissivity composite foil on its reverse surface. Manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP).
CHARACTERISTICS
- Safe and easy to handle and install,
- Water vapour resistant,
- Fire rated - Euroclass: C-s2,d0,
- Non-deleterious,
- Very durable, depending on the structure and conditions of use,
- Unaffected by air filtration,
- High performance thermoset rigid insulation,
- Applicable in both new build and refurbishment projects,
- Environmentally friendly, with 0 ODP and low GWP.
APPLICATION
Kingspan Kooltherm K110 Soffit Board is used for structural ceilings, including:
- concrete soffits;
- timber battens and
- proprietary grid systems.
INSTALLATION
- Insulation boards should be installed with joints lightly butted.
- The number of mechanical fixings required will vary with the geographical location of the building, the local topography, the height and width of the soffit concerned, and the soffit construction.
- A minimum of 11 mechanical fixings, with a minimum head diameter of 35 mm, are required to secure the insulation board to the soffit.
- Where the insulation boards may be subject to external wind pressure, the requirement for additional fixings should be assessed in accordance with BS/I.S. EN 199114: 2005 (National Annex to Eurocode 1 Actions on Structures. General Actions. Wind Actions).
- The fixings should be evenly distributed over the whole area of the board, and must offer a minimum 40 mm penetration into a solid substrate.
- Fixings at board edges must be located > 50 mm and < 150 mm from edges and corners of the board and not overlap board joints.
- Depending upon the fixing type, insulation boards can also be fitted by a shot fired fixing method, which can result in significantly faster installation times.
CERTIFICATION
- ISO 9001: 2015 (Quality Management Systems. Requirements),
- ISO 14001: 2015 (Environmental Management Systems. Requirements),
- BS/I.S. OHSAS 18001: 2007 (Occupational Health & Safety Management Systems. Requirements)
- ISO 50001: 2011 (Energy Management Systems. Requirements with guidance for use).