Novia VC4000 FR Reflective Vapour Control Layer 1.5m x 50m Roll

Novia VC4000 FR Reflective Vapour Control Layer 1.5m x 50m Roll
Novia VC4000 FR Reflective Vapour Control Layer 1.5m x 50m Roll
Novia VC4000 FR Reflective Vapour Control Layer 1.5m x 50m Roll
Novia VC4000 FR Reflective Vapour Control Layer 1.5m x 50m Roll
Novia VC4000 FR Reflective Vapour Control Layer 1.5m x 50m Roll
Guide Price: £165.37 (£198.44 inc VAT)
60 or more £160.43 (£192.52 inc VAT)
  • Product Code: A1-3877
  • Delivery Time: 1 - 2 days
  • Brand: Novia
  • (Tech. support: 01622678952)
  • Model and Size: 1.5m x 50m
  • Weight: 13.00kg
Our ratings on 29-03-2024:
TrustPilot Review 4.6
4.6 out of 5 - Excellent
Google My Business Reviews
4.8 out of 5

Novia VC4000 FR Reflective Vapour Control Layer 1.5m x 50m Roll

Width: 1500mm
Weight/m2: 0.16kg
Weight: 13kg

Novia VC4000 FR Reflective Vapour Control Layer is a premium quality, high performance, Class B flame resistant, reflective air and vapour control layer (AVCL) in any insulated wall or roof application where high moisture vapour resistance is required. Novia VC4000 FR has a reflectivity of 98%, which will significantly improve both U and r values when correctly installed. Novia VC4000 FR will also provide a very low moisture vapour permeability solution. It is approved for use in high rise applications.

CHARACTERISTICS
  • Lightweight breather membrane,
  • Very low moisture vapour permeability,
  • Premium performance tensile and nail tear strength,
  • EN 13501-1 fire approval,
  • Approved for use in high rise applications,
  • Air and wind tight,
  • Improve U values,
  • Minimises interstitial condensation.
APPLICATION
  • Any insulated wall or roof application where high moisture vapour resistance is required.
INSTALLATION
To walls
  • Ensure upper layers overlap lower layers.
  • Work from the bottom moving upwards and ensuring there are minimum overlaps of 100 mm on the horizontal joints.
  • Do not begin a vertical lap joint within 300 mm of a corner,
  • Vertical laps should be at least 150 mm.
  • Ensure the bottom timber is also protected by an overlap.
  • Fix at suitable intervals with galvanised nails, stainless staples or similar permanent fixings.
To roofs
  • Ensure upper layers overlap lower layers.
  • Work from the bottom moving upwards and ensure there are minimum overlaps.
  • The membrane should be overlapped 200 mm on each side of the ridge.
  • All vertical overlaps must be situated on a rafter and must be sealed.
  • Fix at suitable intervals with galvanised nails, stainless staples or similar permanent fixings.
  • At any entry points for services (soil pipes, vents etc.), ensure that the membrane is properly sealed.
  • Use of Novia breather membrane tapes.
  • Ensure that for wall or warm roof applications, a vapour barrier is installed on the warm side of the insulation.
CERTIFICATION
  • Complies to EN 13501-1 Fire Classification Class B-s1, d0
  • Meets the requirements for UKCA marking,