ARC Cavity Stop Sock for 150mm Cavity - Fire Barrier 160mm x 120mm x 1200mm - Pack of 15

ARC Cavity Stop Sock for 150mm Cavity - Fire Barrier 160mm x 120mm x 1200mm - Pack of 15
ARC Cavity Stop Sock for 150mm Cavity - Fire Barrier 160mm x 120mm x 1200mm - Pack of 15
Our ratings on 24-02-2026:
Google My Business Reviews
4.8 out of 5
Show Other sizes

To get price for this product only fill below:

If you need price for more products use blue button "Add to Quote" and look for more products.

ARC Cavity Stop Sock for 150mm Cavity - Fire Barrier 160mm x 120mm x 1200mm - Pack of 15

Length: 1200mm
Width: 160mm
Thickness: 120mm
Pack Quantity: 15
Fire Protection (Resistance to Fire): 240minutes
Cavity width: 150mm
Sleeve Colour: Light Blue

160mm x 120mm x 1200mm ARC Cavity Stop Sock for 150mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the external wall cavity, in line with a separating wall or floor as specified in Approved Document B, and for closing the cavity at eaves level. ARC Cavity Stop Sock is simply compression fitted as the masonry work progresses. No mechanical fixing is required as the compression fit would hold the barrier in place, as the relevant Cavity Stop Sock is wider than the given cavity.

  

Note: The cavity width must be accurate and the cavity insulation should be cut back where the barrier will be located. Do not remove the cover. All corners and joints must be tightly butt jointed. Cavity Stop Sock barriers should not be bent around corners. Excess polythene should be removed, so Cavity Stop Sock can be tightly butt jointed.


CHARACTERISTICS
  • Up to 4 hours fire integrity,
  • Can be installed horizontally and vertically,
  • Easily installed with compression fit,
  • No mechanical fix is required,
  • Specified in terraced, semi-detached, apartments and major projects,
  • Meets requirements of Robust Detail Part E and Approved Document B.
INSTALLATION
  • The ARC Cavity Stop Sock must fully fill the cavity from external brick to internal block.
  • Any cavity insulation must be cut back at the location of the barrier.
  • Care must be taken to ensure that the built cavity width is accurate.
  • Use appropriate ARC Cavity Stop Sock for the given cavity width.
  • At the end of a run, or at a corner, lengths of barrier should be cut to the required length, and then tightly butt jointed ensuring no gaps remain.
Vertical application
  • Build up the internal masonry work first.
  • Then progress several courses of brickwork, before installing the barrier.
  • The brickwork can continue, building the barrier in.
  • Care must be taken to ensure the correct compression fit is achieved.
Horizontal application
  • Build the brickwork up to the level the barrier will be installed, ensuring the width of the cavity is correct.
  • Allow the brickwork to set, before push fitting the barrier in to place and under the correct compression.
CERTIFICATION


Brand: ARC Building Solutions Model: TBR150/25
Delivery Time: 2 - 3 working days
ARC T-Barrier Pitched Roof for 150mm Masonry Party Wall Cavity is a non-combustible rockfibre mineral wool cavity fire barrier that stops fire between party wall and roof covering. ARC T-Barrier Pitched Roof is designed to provide a fire, thermal and acoustic barrier between the top of the party wal..
Brand: ARC Building Solutions Model: TBR50/25
Delivery Time: 2 - 3 working days
ARC T-Barrier Pitched Roof for 50mm Masonry Party Wall Cavity is a non-combustible rockfibre mineral wool cavity fire barrier that stops fire between party wall and roof covering. ARC T-Barrier Pitched Roof is designed to provide a fire, thermal and acoustic barrier between the top of the party wall..
Brand: ARC Building Solutions Model: CSS155
Delivery Time: 5 - 10 Working Days
165mm x 150mm x 1200mm ARC Cavity Stop Sock for 155mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Brand: ARC Building Solutions Model: CSS140
Delivery Time: 5 - 10 Working Days
150mm x 120mm x 1200mm ARC Cavity Stop Sock for 140mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
Brand: ARC Building Solutions Model: for 100mm Cavity - 115mm x 500mm x 500mm
Delivery Time: 2 - 3 working days
ARC TCB Square is a faster and easier to install cavity barrier around service penetrations in external timber frame walls of low rise houses. It exceeds the Building Regulation part B fire safety norm EI30/15. ARC TCB Square provides a more robust solution, compared with either boxing in using cut ..
Brand: ARC Building Solutions Model: CSS135
Delivery Time: 5 - 10 Working Days
145mm x 120mm x 1200mm ARC Cavity Stop Sock for 135mm Cavity is a non-combustible rockfibre mineral wool cavity barrier that restricts the spread of smoke and flames within the cavity of external and internal party masonry walls. It is ideally suited for providing a cavity fire barrier within the ex..
This product is listed in the following categories and systems (click to show).